Blank Space TheDieselStop.Com is a source of information, discussion, and help pertaining to the full line of Ford trucks, SUVs, and vans with International diesels. We cover everything from the original F-250s with 6.9L diesels all the way up to the newest 2008 Super-Duty trucks with the new 6.4L Power Stroke engine. Blank Space


Menu
FAQ Home
General Information
Maintenance
Tips & Tricks
Trouble Spots
Frequently Asked
  Questions
Help Network
Links
Downloads

APCM Manual for Vehicles with 7.3L DIT Engine
Courtesy of: Ford Motor Company Publication


Introduction
APC Module Display and Key Description
System Checkout
Enabling/Disabling Functions and Station Programming
RPM Control Usage
RPM Memory Re-Programming
Charge Protection Usage
Alternative RPM Memory Re-Programming and Ramp Rate Re-Programming
Diagnostics
Installation Instructions For ACPM Kit
APC Module Usage


Introduction

This kit provides adaptive vehicle "Charge Protection," selectable fixed elevated idle operation, and/or "manual" RPM control.  This kit is compatible with IN-CAB ONLY mounting of the operator interface Auxiliary Powertrain Control Module (APC) Module).  A user programming option allows for deselection of any of the functions.

NOTE: If "power up" RPM control is programmed, elevated idle will occur within a few seconds after the below enabling interlocks are met.

Features Specifications/Display
Enabling interlocks
  • Parking brake engaged
  • Clutch engaged (foot off) or vehicle in PARK
  • Service Brake off
  • Foot off accelerator
  • Brake lights connected and functional
Adaptive "Charge Protection"
  • System voltage display
Minimum activation RPM for charge protection
  • 1300 RPM
Maximum charge rate
  • At 1747 RPM
Selectable idle operation with closed-loop engine speed control
  • System RPM display
Programmable RPM memories
  • 4
Programmable engine speed "up" ramps
  • 4 (1 per RPM memory)
Minimum programmable PRM
  • 1300 RPM
Maximum programmable RPM
  • 2500 RPM
Manual RPM control
  • Via slow and fast up and down switches
Multiple means of returning to idle
  • Press brake or clutch pedal
  • Release parking brake
  • Take vehicle out of PARK
  • Deselect APC module function
  • Turn off power to APC module

Back to Top


APC Module Display and Key Description




Back to Top

System Checkout

NOTE: Before programming the system, install module per separate installation sheet.

NOTE: If "power up" RPM control is programmed, elevated idle will occur within a few seconds after the below enabling interlocks are met.

Ensure That Enabling Conditions Are Met

  • Parking brake set
  • Manual transmission
    • Engage clutch (foot off clutch pedal)
  • Automatic transmission
    • Gearshift lever in PARK
  • Foot off brake
  • Foot off accelerator
  • Brake lights connected and functional

Power Supply Check

  • Start Engine
    • Observe brief display of "8's" followed by engine speed
    • Observe steady light next to POWER key and backlighting on keys

NOTE: See Diagnostic Section (Section IX) if any of the above are not observed.

Functionality Check

  • Stop engine
  • Restart engine
    • Observe brief display of "8's"
  • IMMEDIATELY press CHARGE PROTECT key if "Power Up" Charge Protection is not enabled
    • Observe flashing light next to CHARGE PROTECT key
  • If batteries are fully charged, no high current draw accessories are on, and engine is fully warmed, observe elevated engine speed sound equivalent to 1300 RPM
  • Observe display of nominal system voltage

NOTE: If engine is not fully warmed (glow plugs are on initially after start), very high electrical loads exist, or batteries are significantly discharged, engine speed will be greater than 1300 RPM.  If electrical loads exceed maximum alternator output (normal with glow plug operation) a below normal system voltage will be displayed.

You have activated the "Charge Protection" function to do this check.  To deactivate this function, do one of the following:

  • Press CHARGE PROTECT key
    • Light next to CHARGE PROTECT key goes out
    • Engine speed returns to vehicle idle
    • Current engine speed is displayed
  • Press brake or clutch pedal, take vehicle out of PARK, or release parking brake
    • Light next to CHARGE PROTECT key goes out
    • Engine speed returns to vehicle idle
    • Current engine speed is displayed
  • Press ACTIVATE/DEACTIVATE (FORD OVAL) key
    • Light next to CHARGE PROTECT key goes out
    • Engine speed returns to vehicle idle
    • Current engine speed is displayed
  • Press POWER key
    • All lights next to keys go out (system is off)

Back to Top

Enabling/Disabling Functions and Station Programming

This unit is shipped with "Charge Protection" Fixed Elevated Idle, and Manual RPM Control activated and "Power Up" Charge Protection and "Power Up" RPM control deactived.  Any of these features can be selected or deselected, either with the engine running or with the key in the "on" position and the engine not running.  NOTE: This kit provides single station operation only.

To Enable or Disable Functions:

  • Ensure that light next to POWER key is lit and engine speed is displayed.  If not, press POWER key
    • Steady light shows next to POWER key
    • Current engine speed is displayed
  • Press ACTIVATE/DEACTIVATE (FORD OVAL), RPM CONTROL, and CHARGE PROTECT keys simultaneously for 3 seconds to activate programming mode
    • Display shows current station setting

      NOTE: For this kit, this value will always be "1".  It cannot be changed.

    • Decimal point flashes on display
    • "VRMP" and "/\RMP" are displayed if Manual RPM Control capability is enabled.
  • Press any arrow key to toggle Manual RPM Control function.
    • "VRMP" and "/\AMP" are disappear if they were previously displayed (Manual RPM Control will be disabled)
    • "VRMP" and "/\AMP" are displayed if they were not previously displayed (Manual RPM Control will be enabled)
  • Press ACTIVATE/DEACTIVATE (FORD OVAL) key to proceed to the next step in programming.  (To exit this programming mode, see the last paragraph of this section.)
    • "V" flashes in upper right corner of display
    • "CHARGE" is displayed if Charge Protect capability is enabled
  • Press any arrow to toggle Charge Protect capability
    • "CHARGE" disappears if it was previously displayed (Charge Protect capability will be disabled)
    • "CHARGE" is displayed if it was not previously displayed (Charge Protect capability will be enabled)
  • Press ACTIVATE/DEACTIVATE (FORD OVAL) key to proceed to the next step in programming.  (To exit this programming mode, see the last paragraph of this section.)
    • "RPM" flashes in lower left corner of display
    • "RPM" is displayed at upper right if Fixed RPM Control is enabled
  • Press any arrow key to toggle Fixed RPM Control capability
    • "RPM" disappears if it was previously displayed (FIXED RPM Control capability will be disabled)
    • "RPM" is displayed if it was not previously displayed (Fixed RPM Control capability will be enabled)
  • Press ACTIVATE/DEACTIVATE (FORD OVAL) key to proceed to the next step in programming.  (To exit this programming mode, see the last paragraph of this section.)

    NOTE: The "Power-up" modes function only for vehicles with automatic transmission.

    NOTE: If either of the "Power-up" functions were canceled prior to entering station programming, and a change is made to Manual RPM Control, Charge Protect, or Fixed RPM Control enabling/disabling, "BASE" will be indicated on the display.

    • If neither Power-up mode is activated, "BASE" will be displayed
    • If Power-up Charge Protect mode is activated, "A CP" will be displayed
    • If Power-up RPM mode is activated, "A Sr" will be displayed
  • Press any arrow key to change to a different "Power-up" mode
    • If neither Power-up mode is activated, "BASE" will be displayed
    • If Power-up Charge Protect mode is activated, "A CP" will be displayed
    • If Power-up RPM mode is activated, "A Sr" will be displayed

CAUTION: SELECTION OF THE "POWER-UP" RPM OR "POWER-UP" CHARGE PROTECT FUNCTION WILL RESULT IN ELEVATED ENGINE RPM WITHIN A FEW SECONDS OF THE VEHICLE'S ENABLING INTERLOCKS BEING MET.

To Exit Station/Function Enable/Disable Programming Before Completing All Steps:

  • Press ACTIVATE/DEACTIVATE (FORD OVAL), RPM CONTROL, and CHARGE PROTECT keys simultaneously for 3 seconds.
    • Current engine speed is displayed

To Exit Station/Function Enable/Disable Programming After Completing All Steps:

  • Press and release ACTIVATE/DEACTIVATE (FORD OVAL)
    • Current engine speed is displayed after the final programming step
  • Press POWER key
    • All lights next to keys go out (system is off)

Back to Top

RPM Control Usage

The RPM Control function provides elevated (minimum 1300 RPM, maximum 2500 RPM) idle engine speed operation with closed-loop control.  When the module is shipped, the four engine RPM memories are pre-set at four intermediate RPM values over the operating range, with a moderate "up" ramp rate.  Manual RPM control is available by using the slow and fast up and down keys.

CAUTION: IF "POWER-UP" RPM CONTROL HAS BEEN PROGRAMMED, ELEVATED ENGINE RPM WILL OCCUR WITHIN A FEW SECONDS AFTER VEHICLE'S ENABLING INTERLOCK CONDITIONS ARE MET.

To Activate RPM Control (If "Power-up" RPM Control has not been programmed):

  • Start engine and ensure that vehicle enabling conditions are met
    • Steady light shows next to POWER key
    • Current engine speed is displayed
  • Press RPM CONTROL key
    • Steady light shows next to RPM CONTROL key
    • RPM stored in Memory #1 displayed
  • If any memory other than Memory #1 is desired, press one of the four arrow keys to recall the engine speed stored in that memory
    • RPM stored in memory selected is displayed
  • Press ACTIVATE/DEACTIVATE (FORD OVAL) key to change the engine speed
    • Light next to RPM CONTROL key blinks
    • Engine speed increases to RPM displayed

To Use Manual RPM Control:

  • Select and activate a pre-set engine speed in "To Activate RPM Control"
  • Press or hold a single arrow (slow) key or a double arrow (fast) key
    • Next engine speed is displayed
    • Light next to RPM CONTROL key blinks
    • When arrow key is released, engine speed displayed becomes a new temporary set point

To Exit RPM Control:

  • Press RPM CONTROL key
    • Light next to RPM CONTROL key goes out
    • Engine speed returns to vehicle idle
    • Current engine speed is displayed
    • "Power-up" RPM Control, if enabled, is canceled for the current ignition cycle
  • Press brake or clutch pedal, take vehicle out of PARK, or release parking brake
    • Light next to RPM CONTROL key becomes steady (system is still in RPM Control mode)
    • Engine speed returns to vehicle idle
    • Engine speed stored in most recently selected memory is displayed
    • "Power-up" RPM Control, if enabled, is NOT canceled.  If vehicle enabling conditions are re-established, RPM Control will be re-engaged
  • Press ACTIVATE/DEACTIVATE (FORD OVAL) key
    • Light next to RPM CONTROL key becomes steady (system is still in RPM Control mode)
    • Engine speed returns to vehicle idle
    • Engine speed stored in most recently selected memory is displayed
    • "Power-up" RPM Control, if enabled, is canceled for the current ignition cycle
  • Press POWER key
    • All lights next to keys go out (system is off)
    • "Power-up" RPM Control, if enabled, is NOT canceled.  If APC is repowered, and vehicle enabling conditions are met, RPM Control will be re-engaged

Back to Top

RPM Memory Re-Programming

Programmable engine speed is limited to a minimum of 1300 RPM and a maximum of 2500 RPM.  The four RPM memories are pre-set at four intermediate values within the operating range.  These setpoints can be changed with the engine running the following method.

To Re-Program An RPM Memory

  • Select and activate the memory you wish to re-program
  • Tap or hold a single arrow (slow) key or a double arrow (fast) key until desired engine speed is reached
    • New engine speed is displayed
    • Light next to RPM CONTROL key blinks
  • Press ACTIVATE/DEACTIVATE (FORD OVAL) key and top arrow key simultaneously
    • New engine speed is stored in memory

To Exit RPM Memory Re-Programming

  • Press RPM CONTROL key
    • Light next to RPM CONTROL key goes out
    • Engine speed returns to vehicle idle
    • Current engine speed is displayed
  • Press brake or clutch pedal, take vehicle out of PARK, or release parking brake
    • Light next to RPM CONTROL key becomes steady (system is still in RPM Control mode)
    • Engine speed returns to vehicle idle
    • Engine speed stored in most recently selected memory is displayed
  • Press ACTIVATE/DEACTIVATE (FORD OVAL) key
    • Light next to RPM CONTROL key becomes steady (system is still in RPM Control mode)
    • Engine speed returns to vehicle idle
    • Engine speed stored in most recently selected memory is displayed
  • Press POWER key
    • All lights next to keys go out (system is off)

Back to Top

Charge Protection Usage

CAUTION: IF "POWER-UP" CHARGE PROTECTION HAS BEEN PROGRAMMED, AUTOMATIC ELEVATED ENGINE RPM WILL OCCUR WITHIN A FEW SECONDS OF THE VEHICLE'S ENABLING INTERLOCK CONDITIONS BEING MET.

To Activate "Charge Protection" (If "Power-up" Charge Protection has not been programmed):

  • Start engine and ensure that vehicle's enabling interlock conditions have been met
    • Steady light shows next to POWER key
    • Current engine speed is displayed
  • Press CHARGE PROTECT key
    • Light next to CHARGE PROTECT key blinks
    • Engine speed increases
    • Battery voltage ramps up (if necessary) and is displayed

To Exit "Charge Protection":

  • Press CHARGE PROTECT key
    • Light next to CHARGE PROTECT key goes out
    • Engine speed returns to vehicle idle
    • Current engine speed is displayed
    • "Power-up" Charge Protection, if enabled, is canceled for the current ignition cycle
  • Press brake or clutch pedal, take vehicle out of PARK, or release parking brake
    • Light next to CHARGE PROTECT key goes out
    • Engine speed returns to vehicle idle
    • Current engine speed is displayed
    • "Power-up" Charge Protection, if enabled, is NOT canceled.  If vehicle enabling conditions are re-established, Charge Protection will be re-engaged
  • Press ACTIVATE/DEACTIVATE (FORD OVAL) key
    • Light next to CHARGE PROTECT key goes out
    • Engine speed returns to vehicle idle
    • Current engine speed is displayed
    • "Power-up" Charge Protection, if enabled, is canceled for the current ignition cycle
  • Press POWER key
    • All lights next to keys go out (system is off)
    • "Power-up" Charge Protection, if enabled, is NOT canceled.  IF APC module is repowered, and vehicle enabling conditions are met, Charge Protection will be re-engaged

Back to Top

Alternative RPM Memory Re-Programming and Ramp Rate Re-Programming

The engine speed setpoints stored in the four memories can be reset in one of two ways: (1) While in RPM Control mode with the engine running as described in this section either with the key on and the engine off or with the engine running.  In addition, the ramp "up" rate for each memory can be reset.  This is the rate at which engine speed will increase when a new setpoint is activated in RPM Control mode.  The ramp "up" rate for each of the four memories is preset at 1/2 of the maximum allowable acceleration rate.  NOTE: The ramp "down" rate cannot be reset.

To Re-Program RPM Memories and Ramp Rates:

  • Ensure that light next to POWER key is lit and current engine speed is displayed.  If not, press POWER key
    • Steady light shows next to POWER key
    • Current engine speed is displayed
  • Press ACTIVATE/DEACTIVATE (FORD OVAL) and RPM CONTROL keys simultaneously for 3 seconds
    • Lights next to POWER and RPM CONTROL keys blink
    • "RPM" blinks in lower left corner of display
    • Engine speed stored in Memory #1 is displayed
  • Press ACTIVATE/DEACTIVATE (FORD OVAL) key and an arrow key simultaneously to select a memory other than Memory #1 to reprogram, i.e..
    • Second arrow key - Memory #2
    • Third arrow key - Memory #3
    • Bottom arrow key - Memory #4
    • Engine speed stored in selected memory is displayed
  • Press or hold an arrow key until desired engine speed setpoint is reached (single arrows provide slow changes; double arrows provide fast changes)
    • New engine speed is displayed
  • Press ACTIVATE/DEACTIVATE (FORD OVAL) key to set engine speed for selected memory and proceed to ramp rate programming
    • /\AMP blinks on display
    • Vertical and horzontal lines show degree of ramp
  • Press or hold arrow keys until desired engine speed ramp up rate is reached
    • Vertical and horizontal lines on display show engine speed ramp up rate (as the rate increases, more lines are displayed)
  • Press ACTIVATE/DEACTIVATE (FORD OVAL) key to set ramp up rate for selected memory

    NOTE: The ramp "down" rate cannot be reset.

  • Press ACTIVATE/DEACTIVATE (FORD OVAL) key to return to RPM memory re-programming.  Another memory can be selected and re-programmed if desired

To Exit RPM Memory and Ramp Re-Programming:

  • Press ACTIVATE/DEACTIVATE (FORD OVAL) and RPM CONTROL keys simultaneously for 3 seconds
    • Light next to RPM CONTROL key goes out
    • Light next to POWER key goes to steady state
    • Current engine speed is displayed
  • Press POWER key
    • All lights next to keys go out (system is off)

Back to Top

Diagnostics

Problem Action
APCM functions but control screen is blank
  • Reprogram the APCM with the latest level calibration
No backlight on ACTIVATE/DEACTIVATE (FORD OVAL) key or POWER key
  • Check power and ground lines
When trying to enter a mode, light next to RPM CONTROL key or CHARGE PROTECT key blinks briefly but does not stay lit
  • Ensure that enabling conditions are met
    • Parking brake engaged
    • Clutch engaged (foot off) or vehicle in PARK
    • Service brake off
    • Foot off accelerator
    • Brake lights connected and functional
  • With APC module turned off, use NGS Tester to determine if there are any brake or clutch pedal fault codes
  • For non-speed control vehicles (1995 MY only):
    • PCM may be incorrect.  For manual vehicles, processor catch-word must be SOD4 or later.
    • For F250/F350/E350 automatic vehicles, processor catch-word must be TEE5 or later
    • For Super Duty vehicles, processor catch-word must be PRY4 or later.  The catch-word tag may be located on the vehicle "A" pillar or on the PCM itself.
Display reads CErr for 5 seconds before normal display activation
  • Check communication lines
    • One may be open or shorted
Display reads CErr
  • Check communications lines
    • Both may be open
  • Check vehicle model year
    • May be pre-1995 (module will not function in earlier model vehicles)
Display reads CrSd
  • Check communication lines
  • If communication lines are OK, replace APC module
Display reads EErr
  • APC component defective - Replace APC module
Display reads AErr
  • APC component defective - Replace APC module





Back to Top

Installation Instructions For APCM Kit

  1. Remove contents of box and examine contents for correct component qualities.
  2. Using the four (4) screws provided (Item #11), attach the APC Module (Item #12) to the Module Bracket (Item #10).  Torque screws to 1.6 - 2.0 Nm.
  3. Snap U-nut (Item #9) onto one end of the Bracket (Item #10) with conical nut projection pointing toward the inside of the angle.  (Refer to sketch.)
  4. Attach the Rear Angle Brace (Item #8) to the Module Bracket Assembly using one of the Screws (Item #6) provided.  Do not fully tighten at this time!
  5. Place Clip (Item #5) around Instrument Panel Support (Item #3), with the flat part of the Clip tangent to the bottom side of the Instrument Panel Support.  (Refer to sketch.)
  6. Remove the two (2) Instrument Panel Attachment Screws (Item #4) as shown.
  7. Place APC Module Assembly under Instrument Panel (Item #1) in position under Ash Receiver Door (Item #2) and attach to flange using the two (2) screws (Item #4) that were removed in Step F.  Torque screws to 2.5 ± 0.4 Nm.
  8. Making sure that the Clip (Item #5) is above the Brace (Item #8), attach the components using the Screw (Item #6) and the Nut and Washer (Item #7 as shown.
  9. Tighten the M6 Fasteners (Item #6) to 12 ± 1.8 Nm.
  10. Attach Wiring Connector (Item #13) to mating connector under Instrument Panel and attach the other end to the APC Module.




Back to Top

APC Module Usage

NOTE: IF SYSTEM IS PROGRAMMED FOR "POWER-UP" RPM OR "POWER-UP" CHARGE PROTECTION, FUNCTION WILL BE ACTIVE WHENEVER THE ENABLING CONDITIONS ARE MET.

To Deactivate "Charge Protect" or RPM Control:

  • Press lighted key for function in use
  • Press ACTIVATE/DEACTIVATE (FORD OVAL) key
  • Press POWER key
  • Press brake or clutch pedal, take vehicle out of PARK, or release parking brake

NOTE: To deactivate "Power-up" RPM Control or "Power-up" Charge Protection, use and of the above methods.  However, note that pressing the lighted key for the function in use or the ACTIVATE/DEACTIVATE (FORD OVAL) key will necessitate a key-off/restart cycle to regain the "Power-up" function.  Pressing the POWER key does not cancel the "Power-up" function.  It will still be enabled if the POWER key is pressed again.

Enabling Conditions:

  • Parking brake set
  • Foot off clutch or gear shift lever in PARK
  • Foot off service brake
  • Foot off accelerator
  • Brake lights connected and functional

"Charge Protect" Activation (If "Power-up" Charge Protection has not been programmed):

  • Press CHARGE PROTEC key
    • Light next to CHARGE PROTECT key blinks
    • RPM increases
    • System voltage is displayed
Fixed Speed RPM Control Activation (If "Power-up" RPM Control has not been programmed):
  • Press RPM CONTROL key
    • Steady light next to RPM COTROL key
    • RPM stored in Memory #1 is displayed
  • If any memory other than Memory #1 is desired, press on the the four (4) arrow keys to recall the engine speed stored in that memory
    • RPM stored in memory selected is displayed
  • Press ACTIVATE/DEACTIVATE (FORD OVAL) key to activate
    • Light next to RPM CONTROL key blinks
    • Engine speed increases to RPM displayed

Manual RPM Control:

  • Select and activate a preset fixed engine speed
  • Press or hold "up" or "down" single arrow (slow) or double arrow (fast) key
    • New engine speed is displayed
    • Light next to RPM CONTROL blinks
    • When key is released, RPM displayed becomes new temporary setpoint
  • To save new setpoint, simultaneously press and hold top arrow key and ACTIVATE/DEACTIVATE (FORD OVAL) key for 2 seconds

Back to Top


This page has been accessed 25,855 times.
All trademarks and copyrights on this page are owned by their respective companies.
All else is Copyright © 1997-2007 TheDieselStop.Com.
All Rights Reserved

TheDieselStop.Com Privacy Statement
Advertising on TheDieselStop

This site is in no way affiliated with Ford Motor Company or International Truck and Engine Corporation.