Printable View (4 KB) |
Article No.
95-06-13 |
-
NO START - 7.3L D.I. TURBO - IDM MODULE - NO DIAGNOSTIC
TROUBLE CODES
- REDUCED POWER - 7.3L D.I. TURBO -
IDM MODULE - NO DIAGNOSTIC TROUBLE CODES
|
| Publication Date: MARCH 27, 1995 |
|
LIGHT TRUCK: |
1994-97 F SUPER DUTY, F-250, F-350
1997 ECONOLINE |
ISSUE:
A "no-start" or "reduced power" condition may occur intermittently
on some vehicles. This may be caused by a short in the
injector circuits or the IDM module.
ACTION:
Follow the diagnostics listed in the Diagnostic Guide and refer to
the following Service Procedure.
SERVICE PROCEDURE
- If, after completion of all the steps in
the Power Stroke 7.3L (DI Turbo) Diesel Diagnostic Guide, you are
unable to pinpoint the cause of the concern, proceed with the
following steps.
- Disconnect the IDM Module connector and
using a DVOM, measure the resistance between the injector circuits
to ground. If it is less than 5 ohms resistance, repair the
short in the circuit and retest.
- If the concern still exists, replace the
IDM module.
| PART NUMBER |
PART NAME |
| F5TZ-12B599-A |
IDM Module |
| |
|
OTHER APPLICABLE ARTICLES:
NONE
WARRANTY STATUS:
Eligible Under The Provisions Of Powertrain 5 Year/100,000 Mile
Warranty Coverage And Emission Warranty Coverage
| OPERATION |
DESCRIPTION |
TIME |
| 950613A |
Check Injector Circuits For
Short-To-Ground And Replace IDM Module - F-250-350, F-Super Duty |
0.4 Hr. |
| 950613B |
Check Injector Circuits For
Short-To-Ground And Replace IDM Module - Econoline |
0.7 Hr. |
DEALER CODING
| BASIC PART NO. |
CONDITION CODE |
| 12B599 |
28 |
OASIS CODES:
602300, 603300, 607000, 607400, 614000, 614500
|
|
|
|